View Associated Devices
The devices that are associated with the templates are listed in the Associated Devices window. Each device row displays the Device Name, Sync Status, Template Application Status, and Applied Date. You can also click Reapply template to reapply the template. Click the Variable Summary icon to display a summary of the variables in the template and the Report () icon to download the Device Template Apply report. Click the Delete () icon to remove the template from the device.
Click Apply Template if you want to apply a template on a device from the Associated Devices window. If you want to reapply the template on all the associated devices in the template, click Bulk Reapply and click Confirm.
The Sync Status can be either Sync or Out-of-Sync. If the status is displayed as Sync, it indicates that the template and device configurations are the same or in sync. If the status is displayed as Out-of-Sync, it indicates that there has been a change in configuration either on the device or in the template since the last time that the template was applied..
The association of the device with the template is not altered by the following conditions:
-
Pending configuration changes on the device – The Sync Status does not change if there are pending configuration changes that have to applied on the device.
-
Deployment of pending configuration changes on the device – The Sync Status does not change after deployment of pending configuration changes on the device.
The table below shows the Sync and Out-of-Sync scenarios that may occur.
Device Configurations Modified After Application of Template on Device |
Template Configurations Modified After Application of Template on Device |
Association Status |
---|---|---|
No | No | In Sync |
Yes | No | Out of Sync |
No | Yes | Out of Sync |
Yes | Yes | Out of Sync |